{"product_id":"ledcure","title":"LEDCure® (Single LED BAND with Display)","description":"\u003ch3 data-end=\"108\" data-start=\"0\"\u003e\n\u003cmeta charset=\"UTF-8\"\u003e \u003cspan\u003eEIT 2.0™ LEDCure® Standard — High-Accuracy UV LED Radiometer for Industrial Process Monitoring\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e The \u003cb data-index-in-node=\"4\" data-path-to-node=\"1\"\u003eEIT 2.0™ LEDCure® Standard (SAL-B1007 Rev 01.02)\u003c\/b\u003e is a compact, highly accurate UV LED radiometer designed to provide essential irradiance and energy density measurements for industrial UV curing applications. Engineered with a focus on simplicity and precision, this instrument delivers reliable data directly on-site, allowing operators to monitor source performance and ensure process consistency without the need for complex external software for primary readings.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-end=\"607\" data-start=\"604\"\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eTechnical Performance \u0026amp; Patented Optical Accuracy\u003c\/h3\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eTotal Measured Optic Response (TMOR™):\u003c\/b\u003e Featuring EIT 2.0’s patented technology, the optics stack is engineered to capture the full spectral output of industrial LEDs. This ensures absolute energy measurements that are consistent across different units and UV sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003eOptimized LED Spectral Response:\u003c\/b\u003e Available in four specific EIT L-Bands (\u003cb data-index-in-node=\"73\" data-path-to-node=\"3,1,0\"\u003eL365, L385, L395, or L405\u003c\/b\u003e), selected at the time of order. Each band provides a flat response over its range with \u003cb data-index-in-node=\"187\" data-path-to-node=\"3,1,0\"\u003e4 OD out-of-band blocking\u003c\/b\u003e to eliminate interference from non-target wavelengths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eWide Dynamic Range:\u003c\/b\u003e Capable of measuring irradiance from \u003cb data-index-in-node=\"57\" data-path-to-node=\"3,2,0\"\u003e200 mW\/cm² to 40 W\/cm²\u003c\/b\u003e and cumulative energy density from \u003cb data-index-in-node=\"115\" data-path-to-node=\"3,2,0\"\u003e0 to 250 J\/cm²\u003c\/b\u003e, making it suitable for high-intensity LED arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eEngineered Precision:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,1,0,0\"\u003eAccuracy:\u003c\/b\u003e Typically \u003cb data-index-in-node=\"20\" data-path-to-node=\"3,3,1,0,0\"\u003e±2% or better\u003c\/b\u003e within the primary range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,1,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,1,1,0\"\u003eRepeatability:\u003c\/b\u003e Typically better than \u003cb data-index-in-node=\"37\" data-path-to-node=\"3,3,1,1,0\"\u003e0.2%\u003c\/b\u003e, providing the stability required to track subtle changes in UV system output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,4,0\"\u003eLambertian Spatial Response:\u003c\/b\u003e The near-cosine response minimizes measurement errors caused by different source geometries or varying distances from the LED head.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1720\" data-start=\"1717\"\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSimplified Operation \u0026amp; Data Visualization\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eIntuitive Interface:\u003c\/b\u003e A single-button design facilitates power, measurement \"Run\" modes, and data viewing, making it accessible for floor technicians and engineers alike.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eHigh-Contrast OLED Display:\u003c\/b\u003e Features clear yellow text on a black background for high visibility in industrial environments. The screen displays:\u003c\/p\u003e\n\u003cul data-path-to-node=\"5,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,1,0,0\"\u003ePeak Irradiance\u003c\/b\u003e (W\/cm²)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,1,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,1,1,0\"\u003eTotal Energy Density\u003c\/b\u003e (J\/cm²)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,1,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,1,2,0\"\u003eLow-Resolution Irradiance Profile\u003c\/b\u003e for immediate visual analysis of the cure cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eUser-Selectable Modes:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"5,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,1,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,1,0,0\"\u003eGraph Mode:\u003c\/b\u003e View the irradiance profile as a function of time directly on the instrument.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,1,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,1,1,0\"\u003eReference Mode:\u003c\/b\u003e Allows a \"baseline\" run to be stored in memory for instant comparison against current process conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eSelectable Sampling Rates:\u003c\/b\u003e Adjustable \"Smooth\" modes provide effective sample rates of \u003cb data-index-in-node=\"87\" data-path-to-node=\"5,3,0\"\u003e25, 128, or 2048 Hz\u003c\/b\u003e to match the dynamics of different curing speeds and pulse rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2690\" data-start=\"2687\"\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eIndustrial-Grade Design \u0026amp; Reliability\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003eRugged Construction:\u003c\/b\u003e Encased in a durable \u003cb data-index-in-node=\"42\" data-path-to-node=\"7,0,0\"\u003ealuminum and stainless steel housing\u003c\/b\u003e (~117 mm x 12.7 mm) designed to withstand the rigors of production environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003eThermal Management:\u003c\/b\u003e Rated for internal operation between \u003cb data-index-in-node=\"57\" data-path-to-node=\"7,1,0\"\u003e0–75°C\u003c\/b\u003e with an audible over-temperature alarm to protect sensitive electronics during high-heat exposures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003eField Serviceability:\u003c\/b\u003e Powered by \u003cb data-index-in-node=\"33\" data-path-to-node=\"7,2,0\"\u003etwo user-replaceable AAA alkaline batteries\u003c\/b\u003e, providing approximately 20 hours of continuous operation with the display active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003eTraceable Calibration:\u003c\/b\u003e Each unit is supplied with a \u003cb data-index-in-node=\"52\" data-path-to-node=\"7,3,0\"\u003eNIST-traceable calibration certificate\u003c\/b\u003e, ensuring compliance with global quality standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3578\" data-start=\"3575\"\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eCore Benefits for Process Control\u003c\/h3\u003e\n\u003cp data-path-to-node=\"9\"\u003eThe \u003cb data-index-in-node=\"4\" data-path-to-node=\"9\"\u003eLEDCure Standard\u003c\/b\u003e empowers Blaze Technology teams and process professionals to:\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eValidate Cure Targets:\u003c\/b\u003e Ensure that irradiance and dose levels meet engineered specifications for specific chemistries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eMonitor Source Degradation:\u003c\/b\u003e Detect intensity drops early to schedule maintenance before product quality is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eEnsure Unit-to-Unit Consistency:\u003c\/b\u003e Use the TMOR™ technology to match performance across multiple production lines or facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"11\"\u003eThe EIT 2.0 LEDCure® Standard provides a professional-grade, \"point-of-use\" solution for UV LED measurement, combining laboratory-level accuracy with the portability required for modern industrial manufacturing.\u003c\/p\u003e","brand":"EIT 2.0","offers":[{"title":"L365 \/ 40 Watts","offer_id":43523445063758,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true},{"title":"L365 \/ 400 mW","offer_id":43523445096526,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true},{"title":"L385 \/ 40 Watts","offer_id":43523445129294,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true},{"title":"L385 \/ 400 mW","offer_id":43523445162062,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true},{"title":"L395 \/ 40 Watts","offer_id":43523445194830,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true},{"title":"L395 \/ 400 mW","offer_id":43523445227598,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true},{"title":"L405 \/ 40 Watts","offer_id":43523445260366,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true},{"title":"L405 \/ 400 mW","offer_id":43523445293134,"sku":null,"price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0602\/9498\/7854\/files\/LEDCure.jpg?v=1766974144","url":"https:\/\/shop.blazeasia.com\/products\/ledcure","provider":"Blaze Technology Pte Ltd","version":"1.0","type":"link"}